Enter your power station’s rated battery capacity and the total wattage of everything plugged into it. The calculator applies a real-world efficiency factor to estimate how long the battery can run that load.
- Usable watt-hours
- –
- Estimated runtime
- –
Quick reference: common appliances
| Appliance | Typical draw | Estimated runtime |
|---|
Each row assumes that appliance runs alone at a steady draw. Real devices cycle on and off (fridge compressors, CPAP humidifiers), so check the wattage on your device’s label or manual.
Why the calculator uses 85% usable capacity
The capacity printed on a power station (for example, 1,024 Wh) describes the energy stored in the battery cells. Not all of it reaches your devices. The inverter that converts the battery’s DC power into 120 V AC loses energy as heat, and the battery management system (BMS), display, and cooling fans draw their own power while the unit is on.
As a general rule, 85% of rated capacity is a realistic baseline for AC output at moderate loads. Direct DC outputs such as USB-C skip the inverter, so they deliver a higher share (about 92%). Heavy loads near the inverter’s limit and idle consumption over long, low-wattage runs pull usable energy down toward 80%. These factors come from manufacturer specifications and standard inverter efficiency ranges. Our Editorial Methodology explains how we apply them across every guide and calculator.
The formula
Usable Wh = Battery capacity (Wh) × Efficiency factor
Runtime (hours) = Usable Wh ÷ Total load (W)
Example: 1,024 Wh × 0.85 = 870 usable Wh. At a steady 150 W load, that is 870 ÷ 150 ≈ 5 hours 48 minutes.
Planning a recharge? Use the Solar Charging Time & Array Sizing Calculator, or see every tool on the Sizing & Calculators hub.